It is used for radiation detection and measurement. It can be also used as a dosimeter.
| Measurands: |
Dose rate, dose, decay per second |
| Measuring elements: |
Two Geiger-Muller tubes, external probe |
| Information display: |
Digital, analogue, automatic adjustment |
| Measuring range: |
od 0.5 μSv/h do 5Sv/h (dose rate), 0.05 μSv to 5 Sv (dose) |
| Start-up time: |
2 s |
| Alarm degrees: |
Adjustable and fixed: |
| |
dose 5 μSv |
| |
dose rate 10 μSv/h, 1 mSv/h |
| Power source: |
2x1.5V, 12/24V AC, 220V |
| Service life: |
500 ur |
| Operating temperature: |
-30 to +55°C |
| Storing temperature: |
-55 to +85°C |
| Barometric pressure: |
60 – 120 kPa |
| Resistance to falls: |
1 m on hard surface |
| Dimensions: |
270 x 230 x 70 mm |
| Weight: |
2.5 kg |
| Humidity: |
0-100%, 1 m under water surface |